CellVoyager CQ1 Benchtop High-Content Analysis System

Easy to use, intuitive, simple acquisition software increases productivity

Compact design contains multiple, fully integrated functions

CSU W-1 confocal spinning disk technology results in higher scanning speeds and higher quality images

Systems open platform allows for integration for laboratory automation

Supports the CellPathfinder high content analysis system


Detail

Product Principles

Principles of the Microlens-enhanced Nipkow Disk Scanning Technology

A Nipkow spinning disk containing about 20,000 pinholes and a subsidiary spinning disk containing the same number of microlenses to focus excitation laser light into each corresponding pinhole are mechanically fixed on a motor, and very rapidly rotated. As a result, a high-speed raster scan of the excitation lights on the specimen can be achieved. The pinhole and microlenses are arranged on each disk in our proprietary design to optimize the raster scan. Multi-beam scanning not only increases scanning speed but also results in significantly lower photobleaching and phototoxicity because multi-beam excitation needs only a low level of laser power on the specimen to fully excite fluorescence.


共聚焦原理.png


Brief Introduction

With its compact footprint and lightweight, benchtop design, there is no need for a darkroom or specialized setup for the CellVoyager CQ1. The unit provides rich feature extractions, facilitating sophisticated cellular image analysis, and while the Nipkow Spinning Disk Confocal Technology allows high speed scanning, it reduces phototoxicity and photobleaching.


新CQ1_AME7323-小.png


Product Characteristics

Enables measurement of spheroids, colonies, and tissue sections

  • No need to remove cells from the culture dish, in contrast to traditional flow cytometry

  • Nipkow spinning disk confocal technology allows high-speed yet gentle 3D image acquisition

  • Rich feature extraction to facilitate sophisticated cellular image analysis

  • Wide field of view and tiling capability enables easy imaging of large specimen

 

Enables analysis of time-lapse and live-cell

  • High precision stage incubator and low phototoxicity of our confocal makes the analysis of time-lapse and live-cell are possible.

  • Max. 20fps option for fast time-lapse.

 

High-quality image and similar operability to a traditional flow cytometer

  • Integration with CellPathfiner software can provide powerful analysis displayed in real-time with image acquisition.

  • Usable high-quality image as confocal microscope image.

  • Interactive graphs make it easy to trace back the data points.

 

Open platform

  • Connectable with external systems via handling robot.

  • Expandable to the integrated system as image acquisition and quantification instrument.

  • FCS/CSV/ICE data format readable by third-party data analysis software.

  • A variety of cell culture and sample dishes are applicable.

 

 

Compact footprint, lightweight bench-top device; no need for a darkroom.


Application Fields

Typical application areas include:

  • Cell biology research;

  • Organoid research;

  • Neurobiological research;

  • Stem cell research

  • Drug screening


Application

1、3D Measurement

The CQ1 is the easiest way 3D measurement system. Simple cell identification, colony counting, and complex colony property analysis are available. Of course you can do whole well imaging and analysis。

 

Example 1:Quality Control: Aggregated cell images were taken in slices and presented as 3D. Marker expression level as well as spatial information of individual cells were quantified via image analysis.

Template: Spheroid structure: Cell-by-cell measurement of aggregated, cells like spheroids.

Applications: Sheroids, Differentiation


应用1-1.png


Example 2:Quality Control:Sphere shape and pluripotencymarker expression level are suitable index for evaluation of quality of pluripotent state of human iPSC sphere.

Template: Colony measurement: Cell-by-cell measurement of aggregated, cells like spheroids.

Applications: Colony growth evaluation, Differentiation.


应用1-2.png


2、High Content Analysis

High quality confocal images from the CQ1 can be used for more detailed image analysis. Morphology change, particle analysis and other. High Content Analysis that require high resolution images. Of course the CQ1 can work like simple Confocal Microscopy to get a nalyzed data and images.

 

Example 1: Analysis: gamma-H2AX focus formation

The phosphorylation of histone H2AX Ser139 (gamma-H2AX) is one of the significant events upon the breakage of double strand DNA. Quantitative measurement of gamma-H2AX focus formation can be easily performed by using the high-speed confocal image acquisition in combination with the Granule Analysis Template.

Template: Dots in Nucleus: Measurements of dots in cytoplasm and nuclei, Precise separation of individual dots by the confocal unit.

Applications: FISH, GPCR.


应用2-1.png


Example 2: Nuclear translocation

NFκB is one of the famous transcription factor of DNA. NFκB plays a key role in regulating the immune response and inflammation and is attracting attention as a tumor therapy and anti-inflammatory drug target. NFκB is located in the cytoplasm with IκB which is inhibitory protein. Once the signaling pathway has been activated by the cytokine stimulation via cell membrane receptor, dissociate IκB from NFκB and activate NFκB. Then NFκB translocate into the nucleus to bind specific sequence of DNA, which induce inflammation. Nucleus and intracellular NFκB level indicates protein level between cytoplasm and nucleus.

Template: Nucleus and Cytoplasm: Measurements of nuclei and cytoplasm, Precise separation of localization by the confocal unit.

Applications: Nuclear translocation, Membrane translocation


应用2-2.png


3、Time Lapse Imaging

Keep cells happier in incubator to see how they react on live. The CQ1 is installed with Yokogawa's proprietary technology CSU, which is very gentle to cell-friendly, low photobleaching and low phototoxicity. Long-term time lapse are possible while minimizing the effects of multiple measurements.

 

Example1:Time lapse analysis: Apoptosis

Spread HeLa cells to 96well microplate with 10,000 cells/well. Stain with Hoechst 33342 (1 µg/ml, 30 min, 37 °C) and treat with Staurosporine (0 - 10µM) and capture image every 15 min. Recognize DNA fragmentation area of nuclei at Staurosporine 10 µM treatment.

Template: Nucleus: Measurements of Volume, Intensity and Morphology

Applications: Cellcycle, Apoptosis.


应用3-1.png


Example 2: Time lapse analysis: ESC colony

Time lapse analysis of colony size and individual cells allow to monitor colony formation state. CQ1ʼs image can perform image acquisition with low photo-toxicity.

Template: Colony measurement: Time course measurement allows to monitor cell colony growth.

Applications: Cell colony growth, Differentiation.


应用3-2.png


4、CTC (Circulating tumor cells)

CTCs are tumor cells which circulate in peripheral blood. Developed tumors metastasize through the bloodstream and lymph fluid. Therefore, tumor cells exist in the bloodstream when metastasis occurs. The detection of CTCs makes it possible to diagnose recurrence and metastasis at an early tumor stage. CTCsʼ numbers are very small as only less than 100 CTCs are contained in more than 1x106 of blood cells in 10 ml of cancer patientʼs blood. Therefore it is difficult to detect CTCs with a flow cytometer because they detect CTCs as noise. However, it is very easy to detect rare CTCs with an Image cytometer.

Template: CTC: You can detect multiple marker expression of the cell. Not only for circulating tumor cells, but also for the other specific marker can be detected.


应用4.png


5、Cell cycle analysis: M-phase inhibitor

Cell cycle analysis in relation to H3Ser10P immunofluorescence by utilizing the CQ1ʼs multi-color channel capabilities. Histone molecules are phosphorylated during cell cycle progression with phosphorylation of the 10th serine of histone H3 being one of the well characterized events of late-G2 to M progression.

Template: CellCycle: You can detect cell cycle to verify drug treatment efficiency. This is available by the flow cytometer, but CQ1 can analyze more items which typical at the image cytometer.


应用5.png


6、CellPathfinder software

The dedicated analysis software "CellPathfinder" can analyze a large amount of image data from multiple angles and easily lead to a graphical display. In addition to the machine learning function, the new Deep Learning option dramatically improves the recognition of analysis targets, making it powerful not only for bright field image analysis, but also for difficult analysis such as 3D culture systems and live cell imaging.


应用6.png


Video

Case

Message

江南JN体育登录入口是集自主研发、海外先进技术国内整合转化和引进海外前沿产品为一体的生命科学 仪器专业服务平台。